Question:

I have installed the 16 bit Windows runtime of Entera 3.2 TCP
but dceinc.h and dceerr.h appear to make calls to include DCE
header files.  Why is this the case?

Answer:

The setup program for 16 bit TCP Entera for Windows copies
incorrect versions of dceinc.h and dceerr.h from the CD.  The
solution is to install the 32 bit version of the runtime in a
temporary directory and copy dceinc.h and dceerr.h from the
$ODEDIR\tcp\include directory from the 32 bit installation to
the $ODEDIR\tcp\include directory for the desired 16 bit
version.  The files are simply header files and there is no
difference between the 16 and 32 bit versions.